The compact, light-weight design makes the Omni TUF-200H handheld flowmeter truly portable. The main unit weights about 1.2lbs only. The rugged aluminum-alloy case allows the flowmeter to be used in harsh environment. The unique clamp-on fixture design makes the installation very simple and no special skills or tools are required. Due to the non-intrusive nature of the clamp-on technique, there is no pressure drop, no moving parts, no leaks and no contamination.
The TUF-200H is ideal for general flow survey, HVAC hydronic balancing / testing, energy consumption supervision, water conservation management, beverage and food processing, chemical process monitoring, power plant monitoring, and other closed-pipe applications where non-intrusive measurement is required. Benefited from our advanced digital signal processing technology, the handheld flowmeter works reliably in both clean and opaque liquid flow. Examples of liquids included but not limited to variety of water (hot/chilled water, city water, sea water), sewage and drain water, oil (crude / diesel / fuel), chemicals (alcohol, acids, etc.), beverage, food, water/glycol solutions, and other liquids.
TUF-200H Kit includes handheld meter, transducers for pipe sizes 15mm - 700mm, magnetic clamping fixtures, chains, tape measure, lubricant, manual, mains charger, aluminum carry case.
| Specification |
| Linearity |
0.5% |
| Repeatability |
0.2% |
| Accuracy |
Normally better than ±1%. Could be ±0.5% with on-site calibration. |
| Response Time |
0-999 seconds, user-configurable |
| Velocity |
±0.03 - ±105 ft/s (±0.01 - ±32 m/s), bi-directional |
| Pipe Size |
1/2" - 240" (DN15mm - DN6,000mm) |
| Pipe Material |
All metals, most plastics, concrete, lined pipe |
| Units |
English (U.S.) or metric |
| Totalizer |
7-digit totals for net, positive and negative flow respectively |
| Liquid Types |
Virtually all clean liquids and liquids with minor solids (<10,000ppm). Full pipe |
| Liquid Temp |
32˚F - 212˚F (0˚C - 100˚C) |
| Security |
Setup values Modification Lockout. Access code needs unlocking |
| Display |
4x16 letters |
| Computer Interface |
RS232 |
| Supplied Transducers |
M1 and S1 As Standard |
| Transducer Cable |
Standard 2x15' (2x5m). Contact sales for longer cable needs |
| Power |
3 AAA Ni-H built-in batteries. When fully recharged it will last over 10 hours of operation. AC Adapter supplied for charging and continuous use. |
| Data Logger |
Over 2000 lines of data |
| Handset Weight |
1.2lbs (538g) |
| Transducer Specifications |
| Type S |
Handheld small size transducer (magnetic with handle). Dim 7.9”x1”x1”, handle length 3.9” For pipe size ½” – 4” |
| Type M |
Medium size transducer (magnetic with mounting rack). Dim 11”x1.6” For pipe size 2” – 28” |
| Type M1 |
Standard medium size transducer (magnetic with clamp-on fixture) Dim 2.4”x1.8” For pipe size 2” – 28” |
| Type L1 |
Large size transducer (magnetic with clamp-on fixture) Dim 3.1”x3” For pipe size 11” – 240” |
|