LogBox data loggers are available with two analogue or a single analogue and digital counter input. Ideal for applications such as flow monitoring, with there robust design and waterproof casing for easy installation. Downloading and configuration is via an infra red interface allow for PC, Laptop or PDA configuration options.
Max. frequency: 4000 Hz (NPN or PNP) or 20 Hz (dry contact)
Maximum counting: 65,535 per period.
Channel 2: 0-20mA, 4-20mA, 0-50mV and 0-10Vdc
Memory capacity: 32k readings
Interval between readings: 1 second to 18 hours
External battery switch time: 0 to 10 s
Power: Internal 3.6V lithium battery (1/2 AA)
Estimated autonomy: Over 2000 days (one daily download)
Memory retention 10 years without power
Working temperature: From –40°C to 70°C.
Protection: IP65, IP67 and IP68 models (see lateral label on product)
Material: ABC + PC case, Polycarbonate film
Dimensions: 60x70x35mm
LogBox-DA is an electronic data logger with two input channels, one analogue and one digital. Input data is stored in the logger internal memory, for later download to a PC for visualization and analysis in the form of tables or graphs. The data is easily exported to spreadsheets.
The LogChart-II is the software used to configure the logger, download and visualize data. The logger configuration allows defining the logger operation mode, including programming the start/stop time of data acquisition. Other parameters such as signal input type, logging interval, multiplication factor, scale range, etc, are easily selected through the LogChart-II software.
The LogBox-DA also provides a signal for commanding an external power supply (battery) of a device connected to the logger. This feature allows that external devices, such as a transmitter, be powered only during the measurement sample time, thus extending the autonomy of these external batteries.
LogBox-AA replaces the digital channel with a second analogue channel that can also accept the below temperature sensors.
Use our online calculator to work out input signal ranges and scaling in engineering units for data loggers. Also calculates shunt resistor values, resolution and null point offsets.
For further information,
technical advice, or a
quotation please call or
email
us. If you are not sure which
product you need one of our
technical sales advisors will be
happy to discuss your
application. We also accept
company purchase orders by fax
or post. Credit card orders can
also be placed over the phone
for any product.
priceaus
ref
description
downloads
price($AUD)
Order Item
8813001000
LogBox-DA IP65 Data Logger, 1 Analogue & 1 Digital input, for 0-50mV,0-10v and 4-20mA inputs, pulse inputs (NPN or PNP up to 4 KHz) or dry contact (up to 20 Hz), with 32,000 rdg memory, battery life up to 3 years. Sensor external power switch.
Packing and postage, 500 gram Express Post package, suitable for 2-3 loggers and IR download lead and software.
10.00
CAR-AUST
3 Kg Express Courier satchels, suitable for orders of 6-10 loggers with download lead and software. Usually, Overnight next day delivery
25.00
8813002000
LogBox-AA IP65 Data Logger, 2 Analogue Channels for Pt100, Thermocouples (types J, K, T, E, N, R, S or B), voltage (0 to 50 mV or 0 to 10 V), or current (0 to 20 mA or 4 to 20 mA). with 32,000 reading memory, battery life up to 3 years. Sensor external power switch.