Contact our technical sales team now to discuss your requirement

( +61 (0)282 442 363  

*  info@omniinstruments.com.au

( +44 (0) 845 9000 601  

*  info@omniinstruments.co.uk

( +1-866-849-3441  

*  info@omniinstruments.net

Request a Quote

click here to send us your enquiry for our immediate attention

 
  Home  |  About Us  |  Former Omni Site  |  Terms and Conditions  |  Links  |  Sitemap |  Basket
 
 

 

Products

Data Loggers

Displacement Sensors

Display & Control Products

Flow Meters

Gas Detection Equipment

Gyros and Accelerometers

Hire Equipment

Level Sensors

Load & Torque Sensors

Pressure Sensors

Radio & GSM Telemetry

Stock Clearance Items

Temperature and Humidity

Test & Calibration

Vibration Monitoring

Voltage & Current Sensors

Weather Stations and Instruments

 
 

Displacement Sensors \ Linear Position Sensors \ LIPS P106 internally mounted cylinder sensor with external electronics

 

«« previous product   4 / 7   next product »»

LIPS P106 internally mounted cylinder sensor with external electronics

The P106 Inductive Linear Position Sensor is an in cylinder with external electronics. It is a highly accurate, durable and affordable position sensor designed for demanding hydraulic or pneumatic cylinder position feedback applications where environmental resistance, cost and service life are particuarly important. It is particuarly suited to OEM customers who require good sensor performance where the internal length or diameter is limited.
 
 
 
 

 

 
 

Product details

 

Specification

Dimensions  
Probe Housing Diameter
20mm
Probe Length
Measurement length + 62mm
Electonics Module Diameter
35mm

Electronics Module Length

40mm-47mm see drawing

Travel

any stroke from 20 mm to 600mm (eg 305mm)

Independant Linearity

<±0.25% up to 450mm <±0.50% over 450mm at 20°C

Temperature Coefficient

<±0.01%/°C Gain & <±0.01%FS/°C Offset

Typical Overall Accuracy

<±0.75% FSO  

Resolution

Infinite

Noise

<0.02% FSO

Frequency Response

>10KHz (-3dB)
>300Hz (-3dB); 2 wire 4-20mA

 

Output Signal and Output Load

Output Signal Output Load

 

0.5 to 4.5 V dc ratiometric 2 K Ohms min

 

0.5 to 4.5 V dc 2 K Ohms min

 

± 5V dc 2 K Ohms min

 

± 10V dc 5 K Ohms min

 

0.5 to 9.5 V dc 5 K Ohms min

 

4 to 20mA (2 wire) 300 Ohms @ 24V

 

4 to 20mA (3 wire sink) 950 Ohms @ 24V

 

4 to 20mA (3 wire source) 300 Ohms Max

Supply Current

12 mA Typical 20 mA max. (Voltage Versions)  

 

Temperature Limits

 

Operating

-40 to +125°C (5V input only)
-20 to +85°C

Storage

-40 to +125°C

EMC Performance

 

Susceptibility

EN 61000-6-2

Radiated

EN 61000-6-3

 

 

Vibration

IEC 68-2-6: 10g

Shock

IEC 68-2-29: 40 g

MTBF

350,000 hrs 40°C Gf

Sealing

IP65(connector) / IP67(cable)

Hydraulic Pressure

350 Bar

Electrical Connections

Screened 3 core cable or integral connector
 

Components / Downloads

 
For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
 

ref

description

downloads

price($AUD)

Order Item

P106

LIPS® 106 internally mounted cylinder sensor with external electronics

 

Data Sheet

 

Drawing

 

900.00

Not Available online

 
 
 

 Tel +44 (0) 845 9000 601  Fax +44 (0) 845 9000 602 info@omniinstruments.co.uk        Tel +1-866-849-3441  Fax +1-866-628-8055  info@omniinstruments.net 

  Tel +61 (0)282 442 363  Fax +61 (0)294 751 278  info@omniinstruments.com.au

| Home  |  About Us  |  News / New Products  |  Old Omni Site  |  Terms and Conditions  |  Links  |  Sitemap | Web Design |