Fast, High Resolution Data Logging
With its high resolution and fast Analog to Digital converter (ADC), DaqPRO meets the majority of data logging requirements in most industrial applications. Its unique ability to display measured values and analyze them in real-time on a graphical interface minimized the need to download collected data to a computer for further analysis.
Applications
- Quality assurance
- Plant and machine condition monitoring
- Field monitoring stations
- Automotive testing
- HVAC
- Plant trouble shooting
- Electricity transients failure detection
- Monitoring environmental conditions
- Food, drug and electronic equipment storage
- Water quality testing
- Research
Accessories
- Carrying case
- NTC temperature probe
- Solar cell and battery for field data logging
- Weather box complies with the IP-67 standard for protecting DaqPRO while working in field applications
Product Features
- Stand-alone operation - samples and displays measurements without being connected to a PC
- Operates on a 7.2V rechargeable battery with over 500 charging cycles
- High sampling of up to 4,000 samples per second in all inputs
- Large data storage of 512KB RAM
- Large graphic display showing collected data as measured values, graphs or tables
- Setup via the DaqPRO keypad
- Fast communication channels: USB
- Multiple logging storage of up to 100 sampling sessions
- Ability to scale readings into meaningful engineering units e.g. bar, ppm
- Built-in clock and calendar keeps track of time and date for each data recording
- On screen text editing for adding more information to the collected data
- Powerful analysis software for Windows 98, 2000, XP and Vista
- Most economical eight channel data logger on the market
Specifications
DaqPRO 5300 8-Input Channels Measure
0 – 24.000 mA
- Range 0 to 20mA
- Resolution 0.47µA
- Accuracy ±0.5% of reading Loop impedance - 21Ω
0 – 50.000 mV
- Range 0 to 50mV
- Resolution 3µV
- Accuracy ±0.5% of reading
- Loop impedance - 50Ω
0 – 10.000 V
- Range 0 to 10V
- Resolution 200µV
- Accuracy ±0.5% of reading
- Loop impedance – 125KΩ
Temperature NTC-1
- NTC – 10KΩ resistor
- Range -25 to 150ºC
- Resolution 0.05ºC
- Accuracy 0.5% of reading
Temperature NTC-2
- NTC – 100KΩ resistor
- Range -25 to 150ºC
- Resolution 0.05ºC
- Accuracy 0.5% of reading
Temperature PT100 2 wires
- Range -200ºC to 400ºC
- Resolution 0.1ºC (7mΩ)
- Accuracy ±0.5% of reading
Temperature PT100 3 wires
- Range -200ºC to 400ºC
- Resolution 0.1ºC (7mΩ)
- Accuracy ±0.5% of reading
Temperature thermocouple J
- Range -200ºC to 1,200ºC
- Resolution 0.1ºC (1µV)
- Accuracy ±0.5% of reading
- Cold junction compensation ±0.3ºC
Temperature thermocouple K
- Range -250 to 1200ºC
- Resolution 0.1ºC (1µV)
- Accuracy ±0.5% of reading
- Cold junction compensation ±0.3ºC
Temperature thermocouple T
- Range -200 to 400ºC
- Resolution 0.1ºC (1µV)
- Accuracy ±0.5% of reading
- Cold junction compensation ±0.3ºC
Frequency input (input 8 only)
- Zero crossing detector
- Sensitivity 20mV
- Range 0.3Hz to 1000Hz
- Resolution 50µs
Internal Temperature
- NTC – 10KΩ resistor
- Range -30 to 70ºC
- Resolution 0.05ºC
- Accuracy 0.5% of reading
|