Contact our technical sales team now to discuss your requirement

( +61 (0)282 442 363  

*  info@omniinstruments.com.au

( +44 (0) 845 9000 601  

*  info@omniinstruments.co.uk

( +1-866-849-3441  

*  info@omniinstruments.net

Request a Quote

click here to send us your enquiry for our immediate attention

 
  Home  |  About Us  |  Former Omni Site  |  Terms and Conditions  |  Links  |  Sitemap |  Basket
 
 

 

Products

Data Loggers - Industrial General Purpose

Displacement Sensors

Display & Control Products Signal Amplifiers

Flow Meters

Gas Detection Equipment

Gyros & Accelerometers IMU's & Tilt Sensors

Hire Equipment

Level Sensors

Load & Torque Sensors

Pressure Sensors

Radio & GSM Telemetry

Stock Clearance Items

Temperature and Humidity

Test & Calibration

Vibration Monitoring

Voltage & Current Sensors Energy Monitoring Systems

 
 

Display & Control Products Signal Amplifiers \ Trip Amps, Signal Converters and Isolators \ 2261 mV - Load Cell Transmitter

 

«« previous product   12 / 52   next product »»

2261 mV - Load Cell Transmitter

The 2261 is a programamble load cell amplifier suitable for 4 wire bridge / strain gauge sensors. Both zero and span are programmable via the front key pad and the LED display allows easy setup.The unit also has NPN/PNP input for external taring and a regulated supply for standard transducers
 
 
 
 

 

 
 

Product details

 
Features
  • Load cell amplifier
  • mV to current / voltage conversion
  • Front-programmable / LED display
  • Relative calibration of input span
  • NPN / PNP input for external taring
  • Supply for standard transducers
Common specifications:
Supply voltage.................................…24 VDC ±20%
Internal consumption ......................… 2.2 W
Max. consumption.............................. 7.2 W
Signal/noise ratio................................ Min. 60 dB
Signal dynamics, input ....................... 17 bit
Signal dynamics, output............... ...... 16 bit
Updating time..................................... 20 ms
Response time, programmable ........ ... 0.06...999 s
Calibration temperature.................. .... 20...28°C
Temperature coefficient..................  ... < ±0.01% of span / °C
Linearity error .................................... ≤±0.1% of span
Effect of supply voltage change..........   < ±0.002% of span/ %V
Auxiliary voltage:
Transducer supply.............................. 5...13 VDC
Load (max)........................................ 230 mA
EMC-Immunity influence............... ..... < ±0.5% of span
Humidity .................................. ........ < 95% RH (non-cond.)
Dimensions (HxWxD).......................... 80.5 x 35.5 x 84.5 mm
Tightness...................................  ...... IP50
Weight ............................................. 130 g


Electrical specifications - Input:
mV-input:
Measurement range ........................... -40...100 mV
Min. measurement range (span).......  .. 10 mV
Max. offset......................................... 70% of selec. max. value
Input in relation to supply gnd.........   ... > - 5 V and < +10 V
Max. cable resistance per wire.......  .... 15 Ω
Suppression of
transducer cable resistance ............... > 300
Input resistance................................. > 10 ΜΩ
Overrange.......................................... 0...999% of selected measurement range
Digital input:
NPN.................................................. Pull up 24 VDC / 6.9 mA
PNP ................................................. Pull down 0 VDC/6.9 mA
Trig level low...................................... < 6 VDC
Trig level high..................................... > 10.5 VDC
Pulse width........................................ > 30 ms

Electrical specifications - Output:

Current output:
Signal range ...................................... 0...20 mA
Min. signal range (span) ..................... 5 mA
Max. offset......................................... 50% of selec. max. value
Load (max.)................................. ...... 20 mA / 600 Ω./ 12 VDC
Load stability ..................................... < ±0.01% of span/100 .
Current limit........................................ < 23 mA
Voltage output through internal shunt:
Signal range ....................................... 0...10 VDC
Min. signal range (span) ................. .... 250 mVDC
Max. offset.......................................... 50% of selec. max. value
Load (min.).......................................... 500 kΩ
Voltage limit ....................................... < 11.5 VDC
Observed authority requirements: Standard
EMC 89/336/EEC, Emission ......   ....... EN 50 081-1, EN 50 081-2
Immunity............................................. EN 50 082-2, EN 50 082-1
 

Components / Downloads

 
For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
 

ref

description

downloads

price($AUD)

Order Item

 
 
 

 Tel +44 (0) 845 9000 601  Fax +44 (0) 845 9000 602 info@omniinstruments.co.uk        Tel +1-866-849-3441  Fax +1-866-628-8055  info@omniinstruments.net 

  Tel +61 (0)282 442 363  Fax +61 (0)294 751 278  info@omniinstruments.com.au

| Home  |  About Us  |  News / New Products  |  Old Omni Site  |  Terms and Conditions  |  Links  |  Sitemap | Web Design |